| NO. | Brand | Compatible P/N | Transceiver Type |
| 1 | Cisco | QSFP-4X10G-AOC30M | |
| 2 | Arista Networks | QSFP-4X10G-AOC30M | |
| 3 | Dell | CBL-QSFP-4X10G-AOC30M | |
| 4 | Juniper Networks | JNP-QSFP-AOCBO-30M | |
| 5 | Extreme | 10GB-4-F30-QSFP | |
| 6 | H3C | QSFP-4X10G-D-AOC-30M | |
| 7 | Brocade | 40G-QSFP-4SFP-AOC-3001 |
| Cisco Compatible |
QSFP-4X10G-AOC30M
|
Vendor Name | HYTOPTODEVICE |
| Connector | QSFP+ to 4 SFP+ | Max Data Rate | 40Gbps |
| Operating Wavelength | 850nm | Fiber Cable | OM3 MMF |
| Cable Length | 30m (98ft) | Power Consumption | ≤1.4W |
| Jacket Material | OFNP | Operation Temperature | 0~ 70 °C (32 to 158°F) |
| Minimum Bend Radius | 30mm | Protocols | 10G/40Gigabit Ethernet or Fibre Channel |
| Application |
InfinibandQDR/DDR/SDR,40G Ethernet,Data Center,Fibre
Channel
|
Warranty | 5 Years |
Usage Guidelines & Best Practices
Mandatory Port Breakout Configuration: Ensure the host QSFP+ port supports channelization. Enable breakout mode (4x10G) via the switch CLI before connecting the cable.
Cabling Requirements: Do not exceed the minimum 30mm bend radius, avoid sharp folding, heavy extrusion or long-term tension on the cable assembly.
Port Installation Standard: Do not mix this breakout AOC with straight QSFP+ to QSFP+ AOC configuration.
Hot‑swap rule:Never pull or tug directly on the individual breakout legs. Always use the integrated pull-tab or bale latch when inserting or removing connectors.
Operating Environment: 0‑70℃, indoor cabinet deployment only.
For detailed operation instructions, please refer to the User Guide.
Full Compatibility List & Supported Devices
Built on MSA open standards, this 40G QSFP+ BREAKOUT active optical cable supports mixed-vendor networking devices. can interoperate with mainstream network brands including Arista, Brocade, Juniper, Dell, H3C and Fortinet, for mixed-vendor rack stacking and server fabric expansion.




Q1: What bend radius rules should I follow when routing these 30m breakout fiber tails in the server rack? A: Maintain a minimum bend radius of roughly 30mm. Any tighter bending will crack internal glass fibers and permanently damage the link of this 40G QSFP+ BREAKOUT active optical cable 30m from our supplier.
Q2: Can this long 40G breakout AOC run full duplex 40Gbps bandwidth simultaneously across all four 10G lanes? A: Yes, it supports full wire-speed 40Gbps aggregate throughput in bidirectional transmission, with four independent 10G channels running at full speed without bandwidth drop.
Q3: Will the 30-meter cable length bring signal jitter and hurt the stability of optical transmission? A: No. Built-in CDR chips inside optical modules suppress jitter automatically, keeping BER at an ultra-low level for reliable long-distance data center transmission.
Q4: Is it possible to set different working speeds on each SFP+ breakout leg of this 40G fanout AOC? A: No. The 40G QSFP+ port is fixed to split into four 10G channels. Individual breakout ports cannot run at 1G or 25G speeds separately.
Q5: What system logs tell me there is an EEPROM coding mismatch on Cisco compatible breakout AOC? A: Typical warning alerts include "Unsupported transceiver detected", "Security checksum error", or "Unqualified optic detected", which indicate incorrect vendor programming.
Q6: Can these 10G SFP+ breakout leads work with legacy 1G SFP ports on older Cisco switches? A: No. SFP+ hardware is designed for native 10G operation and cannot auto-negotiate down to match 1G SFP interface speeds.
Q7: What will happen if I accidentally insert the 40G QSFP+ main plug into a 100G QSFP28 port? A: QSFP+ follows 40G electrical specifications. It cannot establish stable links inside a 100G QSFP28 port unless you deploy special down-conversion adapters.
Q8: Which Cisco switch commands can verify all four breakout sub-channels are properly identified? A: You can run CLI commands such as show interface status or show inventory to check and confirm all four breakout sub-interfaces appear on the port list.
Q9: Can I cascade multiple breakout AOC cables together to extend the cabling distance for my data center project? A: No. Active optical breakout cables cannot be daisy-chained. Series connection breaks the optical path and causes total link failure.
Q10: What troubleshooting actions should I take if only three breakout links come online after installation? A: Check the switch channelization configuration, reseat each SFP+ connector firmly, and review DOM diagnostic data to find the faulty lane.
Q11: Can heavy squeezing or stepping on the cable jacket destroy the internal fiber strands of this breakout AOC? A: Yes. Crushing force can fracture internal glass fibers. The outer jacket may look intact while the optical transmission path is permanently damaged.
Q12: Will this 30m long breakout AOC bring extra weight and trigger port sag on Cisco switch cages? A: No. AOC fanout cables are far lighter than copper breakout alternatives, removing mechanical strain and port sag issues on switch hardware.
Q13: Can technicians splice and repair this AOC on site if the cable gets pinched or cut during installation? A: No. Transceivers are pre-integrated with the cable assembly. Field splicing is impossible, and damaged AOC units need full replacement.
Q14: What after-sales support can I get if the bulk breakout AOC arrives with wrong vendor EEPROM coding? A: As your 40G QSFP+ BREAKOUT active optical cable 30m supplier, HYTOPTODEVICE offers exchange, return or re-programming service for coding compatibility issues upon delivery.
Q15: Can I order custom non-standard lengths instead of standard stocked sizes for my large data center project? A: Standard lengths including 1m,3m,5m,10m,15m,20m,30m,50m are kept in stock. Custom lengths are available for enterprise orders subject to MOQ rules.
Packaging & Custom OEM Solutions
ESD Protection & Fast Shipping: Every transceiver is sealed in an ESD-safe bag and ready for same-day dispatch from stock.
Custom OEM & Branding: We provide logo printing, private labeling, and custom packaging to help distributors and integrators build their brand—no factory investment required.

Why Network Engineers Choose HYTOPTODEVICE
HYTOPTODEVICE has supplied over 5000,000 optical transceiver modules to data centers, ISPs, and enterprise networks across 100+ countries since 2011. Every module undergoes a 72-hour burn-in test and full DDM/DOM validation before shipment.
“Phenomenal performance. We deployed 200 HYTOPTODEVICE SFP modules to replace Cisco OEMs in our backbone network. Result? Zero compatibility issues and a 60% reduction in costs. Highly recommended for mission-critical networks."— Senior Network Engineer, Regional Telecom, Australia
Quality Certification & Compliance
At HYTOPTODEVICE, our quality commitment is backed by industry-standard validations. From fiber optical transceiver manufacturing to final visual inspection, from IQC、IPQC、FQC to OQC, our processes ensure global compliance and reliability.
We adhere to rigorous standards for our SFP modules and network solutions:
ISO 9001: Certified quality management and production consistency.
CE & FCC: Fully compliant for seamless Global Market Access.
RoHS: Committed to environmental responsibility and hazardous material control.
Proven Reliability: Rigorous testing to reduce compliance risk and ensure safety.
Certified Quality. Global Standards. Guaranteed Performance.